You inspire... we materialize®

En savoir plus

You inspire... we materialize®

En savoir plus

You inspire... we materialize®

En savoir plus

You inspire... we materialize®

En savoir plus

Home »   ... »Support » Chemical Resistance Information

Chemical Resistance Information

Our Chemical Resistance Database provides you information on chemicals and fluids known to attack or be compatible with the Quadrant materials listed.

Our database is organized by two product groups. You can access the information on the Quadrant Engineering Plastics below.  For the resistance data on our Symalit® Fluoroplastics (linings) Materials, please click here.

For both databases, please consider the information given as a guideline. For more specific information please contact us.

Quadrant Engineering Plastics - Chemical Resistance Database

Please enter search term:

Concentration (%) Temperature (°C) Duratron® PBI Duratron® PAI Duratron® PEI Ertacetal® C / Acetron® (POM-C) Ertacetal® H / Acetron® (POM-H) Ertalon® / Nylatron® * (PA) Ertalyte® (PET) Fluorosint® (PTFE) Ketron® PEEK * Quadrant® 1000 PC PE 500 / TIVAR® Quadrant® 1000 PSU Quadrant® PPSU Symalit® 1000 PVDF Techtron® HPV PPS
Fat (vegetable oil)
Cas nr.: - Group: Other hydrocarbons (oils, fuels…)
CARTAAAAAAAAAAAAAA
 
Fatty acids - >C6
Group: Organic acids
UDRTAAAAAAAA
5RTAAAAAAAAAA
 
Ferric chloride - FeCl3
Cas nr.: 7705-08-0 Group: Inorganic salt
Synonyms: Iron(III)-chloride
SSRTACABAAAAAA
5RTABABAAAAAAAA
10RTABBAAAAAAAA
50100CCCCABCCAA
 
Ferrous chloride - FeCl2
Cas nr.: 7758-94-3 Group: Inorganic salt
Synonyms: Iron(II)-chloride, Iron dichloride
SSRTACAAAAAAA
SS100CAAAAA
5RTAAAAAAAAAAA
10RTAAAAAAAAAA
 
Fluorine - F2
Group: Halogenes
UDRTCCCCBCCB
 
Fluorosilicic acid - H2SiF6
Cas nr.: 16961-83-4 Group: Inorganic acids
Synonyms: Hydrofluorosilicic acid, Hexafluorosilicic acid
30RTCCCCBAAAA
3060CCCCBAA
50100CCCCCCCA
 
Formaldehyde - HCHO
Group: Aldehydes / Ketones
UDRTACAABAAAAACAA
30RTAAAAAAAAAAAAA
30100BCCCAACCA
 
Formaline - HCOH - CH2O
Cas nr.: 50-00-0 Group: Aldehydes / Ketones
Synonyms: Formaldehyde, Methylene oxide
UDRTACAABAAAAACAA
30RTAAAAAAAAAAAAA
30100BCCCAACCA
 
Formamide - HCONH2 - CH3NO
Cas nr.: 75-12-7 Group: Amides
UDRTAAAAAA
 
Formic acid - HCOOH
Group: Organic acids
UDRTCCCCOBABCAAA
UD100CCCCOCABCAA
2RTCCAABAAAAAAAA
2100CCCCCCAACCAAA
5RTCCABAAAAAAAA
580CCCBCBAABBAAA
10RTCCABCAAABAAAAA
1050CCCCBAAAAAA
50RTCCCCBAABAAAAA
5050A
5075A
50100A
50125B
9060CCCOCABCAA
 
Formol (= formaldehyde 40%) - HCOH - CH2O
Cas nr.: 50-00-0 Group: Aldehydes / Ketones
UDRTAAAAAAA
 
Fruit juices - Fruit juices
Group: Other inorganic chemicals
CARTAAAAAAAAAAAAA
 
Fuel oil DIN 51603 (test mixture A20-NPII)
Cas nr.: - Group: Other hydrocarbons (oils, fuels…)
CARTAAAAAAAACAAAA
 
Furfural - C4H3OCHO
Group: Alcohols / Glycols
UDRTBAAAAAACABA
UD75CAACC
 
Furfuraldehyde - C4H3OCHO
Group: Alcohols / Glycols
UDRTBAAAAAACABA
UD75CAACC
 
Furfuryl alcohol - C4H3OCH2OH
Group: Alcohols / Glycols
UDRTAAAAAA
UD90AAC
 

Legend

Resistance Ratings:

A    :    Resistant. Little or no change in weight. Small effect on mechanical properties. Generally suitable for practical use.
B    :    Partially resistant. In course of time, there is a distinct deterioration in mechanical properties and a change in weight. In many cases a short exposure may be considered allowable.
C    :    Non-resistant.  After a short time, the material is seriously affected (considerable reduction of the mechanical strength and changes in weight). Using the material under these conditions is not recommended.
O    :    The plastics material dissolves in the chemical.

Concentration (%):
A number, e.g. 20, indicates “20 g of solute per 100 g of aqueous solution” (20 % by weight).
UD    :    Undiluted (technically pure chemical)
SS    :    Saturated aqueous solution (at 23°C)
CA    :    As commercially available

Temperature (°C):
RT    :    Room temperature (15 – 25 °C).

* The resistance ratings given for Ertalon®/Nylatron® and Ketron® PEEK are in first instance valid for the unreinforced grades. As far as the glass fibre reinforced grades are concerned (Ertalon® 66-GF30 and Ketron® PEEK GF-30), it has to be noted that they are more affected by hot aqueous solutions than the unreinforced grades. Therefore, preliminary testing under actual service conditions is strongly recommended.

The ratings given here, derived from raw material supplier data and from literature related to the chemical resistance of plastics, are intended as a guide only and not as an alternative to actual testing. Therefore in practice, it is strongly recommended to carry out preliminary tests on a prototype under actual service conditions, to evaluate the final suitability of the selected plastics material for your application.

2007-2013 © the Quadrant group of companies. All rights reserved.

Nous contacter