Please enter search term:
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | saturated; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | B | C | saturated; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | Data valid for lining applications | ||||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | B | C | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | saturated; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | saturated; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | tech. pure; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | tech. pure; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | tech. pure; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | tech. pure; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | C | Concentration :35 : 65; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Concentration : 90 : 10; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Concentration : 90 : 10; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | Concentration : 90 : 10; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | C | traces; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | traces; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | traces; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | B | traces; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | tech. pure; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | C | saturated; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | saturated; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | tech. pure; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | B | C | tech. pure; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | tech. pure; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 40 | A | A | B | 40% aqueous; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 40 | A | A | A | A | A | A | 40% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 40 | A | A | A | A | A | A | 40% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 40 | A | A | A | A | 40% aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | 2% in air; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | B | C | C | C | C | C | saturated; Data valid for lining applications |
Legend
A: Material is resistant
B: Change of properties can occur
C: Material is not resistant due to change of properties
The ratings given here are intended as a guide only and not as an alternative to actual testing. Therefore in practice, it is strongly recommended to carry out preliminary tests on a prototype under actual service conditions, to evaluate the final suitability of the selected plastics material for your application.