| Symalit® ECTFE 1000 linings | |||||
|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||
| 40 | A | A | 40% aqueous; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||
|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | Remarks |
| A | A | A | A | tech. pure; Data valid for lining applications | |
| 40 | A | A | A | A | 40% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||
|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | Remarks |
| A | A | A | A | tech. pure; Data valid for lining applications | |
| 40 | A | A | A | A | 40% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||
|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | Remarks |
| UD | C | tech. pure; Data valid for lining applications | |||
| 40 | C | 40% aqueous; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | tech. pure; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | C | C | Data valid for lining applications | |||
| 10 | A | B | C | 10% aqueous; Data valid for lining applications | |||
| 50 | A | C | 50% aqueous; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | A | A | Data valid for lining applications |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| 50 | A | A | A | A | A | A | 50% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | A | A | Data valid for lining applications |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| 50 | A | A | A | A | A | A | 50% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | B | C | Data valid for lining applications | |||
| 10 | A | A | A | A | 10% aqueous; Data valid for lining applications | ||
| 50 | A | A | C | 50% aqueous; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | tech. pure; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | B | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | B | Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | C | Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | C | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| B | B | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | B | B | C | Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | B | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | B | C | tech. pure; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | B | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | B | C | tech. pure; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| 10 | A | A | A | C | 10% aqueous; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | tech. pure; Data valid for lining applications | |||||
| 10 | A | A | C | 10% aqueous; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | C | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | C | Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | B | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | B | Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | C | Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | B | B | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | B | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | all aqueous; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | B | Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | C | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech.pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | B | tech. pure; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | C | C | saturated; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | saturated; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | saturated; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | saturated; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 96 | A | A | A | Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 96 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 96 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 96 | A | A | Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | A | 50% aqueous; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | A | A | 50% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | A | A | 50% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | 50% aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | all aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated aqueous; Data valid for lining applications | |
| 10 | A | A | A | A | 10% aqueous; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated aqueous; Data valid for lining applications | |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated aqueous; Data valid for lining applications | |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | saturated aqueous; Data valid for lining applications | ||
| 10 | A | A | A | A | 10% aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated aqueous; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | saturated aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated aqueous; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | saturated aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated aqueous; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | saturated aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated aqueous; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | saturated aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | saturated aqueous; Data valid for lining applications | |||
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated aqueous; Data valid for lining applications | |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated aqueous; Data valid for lining applications | |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | saturated aqueous; Data valid for lining applications | ||
| 10 | A | A | A | A | 10% aqueous; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 10 | A | A | A | 10% aqueous; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | B | tech. pure; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | B | C | tech. pure; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||
|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | Remarks |
| 32 | A | A | A | A | 32% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||
|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | Remarks |
| 32 | A | A | A | A | 32% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||
|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | Remarks |
| 32 | C | 32% aqueous; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | C | 100% aqueous; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | 100% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | 100% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | B | 100% aqueous; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech.pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | B | B | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | C | C | all aqueous; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | all aqueous; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | all aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | all aqueous; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | all aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | A | 50% aqueous; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | A | A | 50% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | A | A | 50% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | A | 50% aqueous; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| 10 | A | A | A | A | 10% aqueous; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | saturated; Data valid for lining applications | ||
| 10 | A | A | A | A | 10% aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | B | C | all aqueous; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | all aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | all aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | A | A | 50% aqueous; Data valid for lining applications |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | A | A | 50% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | A | A | 50% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | 50% aqueous; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | all aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | C | C | C | saturated; Data valid for lining applications | ||
| 5 | A | A | A | B | Salmiakgeist; Data valid for lining applications | ||
| Symalit® PVDF Flex linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 30 | A | discoloration possible; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | all aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | saturated; Data valid for lining applications | |||
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | saturated; Data valid for lining applications | ||
| 10 | A | A | A | A | 10% aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | saturated; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | B | all aqueous; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | C | all aqueous; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | all aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | saturated; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | all aqueous; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | all aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | C | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | B | C | tech. pure; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | tech. pure; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | B | tech. pure; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | B | B | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | tech. pure; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | B | B | Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | C | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | B | C | tech. pure; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | B | tech. pure; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | B | C | tech. pure; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | B | tech. pure; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | B | C | tech. pure; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | tech. pure; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | B | C | tech. pure; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | B | B | tech. pure; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 90 | A | B | 90% aqueous; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 90 | A | A | A | A | A | A | 90% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 90 | A | A | A | A | A | A | 90% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 90 | A | A | 90% aqueous; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | up to 90%; Data valid for lining applications | |||
| 6 | A | A | A | A | Data valid for lining applications | ||
| 40 | A | A | A | A | C | Data valid for lining applications | |
| 65 | A | A | A | B | C | C | discoloration possible; Data valid for lining applications |
| 85 | A | A | B | C | C | C | discoloration possible; Data valid for lining applications |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | up to 100%; Data valid for lining applications | |
| 6 | A | A | A | A | A | A | Data valid for lining applications |
| 40 | A | A | A | A | A | A | Data valid for lining applications |
| 65 | A | A | A | A | A | A | Data valid for lining applications |
| 85 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | up to 100%; Data valid for lining applications | |
| 6 | A | A | A | A | A | A | Data valid for lining applications |
| 40 | A | A | A | A | A | A | Data valid for lining applications |
| 65 | A | A | A | A | A | A | Data valid for lining applications |
| 85 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | up to 100%; Data valid for lining applications | |||||
| 6 | A | A | A | A | without UV - light; Data valid for lining applications | ||
| 40 | A | A | A | A | without UV - light; Data valid for lining applications | ||
| 65 | A | A | B | B | ohne UV - Licht Quellung,; Data valid for lining applications | ||
| 85 | A | B | B | B | ohne UV - Licht Quellung und Spannungsrisse; Data valid for lining applications | ||
| 98 | B | Data valid for lining applications | |||||
| Symalit® PVDF Flex linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 6 | A | A | Data valid for lining applications | ||||
| 40 | A | A | Data valid for lining applications | ||||
| 65 | A | A | discoloration possible; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | concentr.; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | concentr.; Data valid for lining applications | ||
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | concentr.; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | B | B | concentr:HCl/HNO3(65%)=2/1; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 80 | A | A | A | A | A | A | 80% aqueous; Data valid for lining applications |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 80 | A | A | A | A | A | A | 80% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 80 | A | A | A | A | A | A | 80% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 80 | A | A | A | A | A | 80% aqueous; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | up to 90%; Data valid for lining applications | |||
| 6 | A | A | A | A | Data valid for lining applications | ||
| 40 | A | A | A | A | C | Data valid for lining applications | |
| 65 | A | A | A | B | C | C | discoloration possible; Data valid for lining applications |
| 85 | A | A | B | C | C | C | discoloration possible; Data valid for lining applications |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | up to 100%; Data valid for lining applications | |
| 6 | A | A | A | A | A | A | Data valid for lining applications |
| 40 | A | A | A | A | A | A | Data valid for lining applications |
| 65 | A | A | A | A | A | A | Data valid for lining applications |
| 85 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | up to 100%; Data valid for lining applications | |
| 6 | A | A | A | A | A | A | Data valid for lining applications |
| 40 | A | A | A | A | A | A | Data valid for lining applications |
| 65 | A | A | A | A | A | A | Data valid for lining applications |
| 85 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | up to 100%; Data valid for lining applications | |||||
| 6 | A | A | A | A | without UV - light; Data valid for lining applications | ||
| 40 | A | A | A | A | without UV - light; Data valid for lining applications | ||
| 65 | A | A | B | B | ohne UV - Licht Quellung,; Data valid for lining applications | ||
| 85 | A | B | B | B | ohne UV - Licht Quellung und Spannungsrisse; Data valid for lining applications | ||
| 98 | B | Data valid for lining applications | |||||
| Symalit® PVDF Flex linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 6 | A | A | Data valid for lining applications | ||||
| 40 | A | A | Data valid for lining applications | ||||
| 65 | A | A | discoloration possible; Data valid for lining applications | ||||
Legend
A: Material is resistant
B: Change of properties can occur
C: Material is not resistant due to change of properties
The ratings given here are intended as a guide only and not as an alternative to actual testing. Therefore in practice, it is strongly recommended to carry out preliminary tests on a prototype under actual service conditions, to evaluate the final suitability of the selected plastics material for your application.