2 - butenal - CH3CH:CHCHO Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
Atech. pure; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDABtech. pure; Data valid for lining applications
2 - chloroethyl alcohol - ClCH2CH2OH Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAtech. pure; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAtech. pure; Data valid for lining applications
2 - propanol - CH3CH(OH)CH3 Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAtech. pure; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAABtech. pure; Data valid for lining applications
2,2,4-trimethylpentane - (CH3)3CCH2CH(CH3)2 Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAtech. pure; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAAtech. pure; Data valid for lining applications
2,5-furandione - C4H2O3 Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAData valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAData valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAData valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAData valid for lining applications
2,6-dimethyl-4-heptanol - [(CH3)2CHCH2]2CHOH Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAtech. pure; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAAtech. pure; Data valid for lining applications
2,6-dimethyl-4-heptanone - (CH3)2CHCH2COCH2CH(CH3)2 Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAtech. pure; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAABCtech. pure; Data valid for lining applications
2-amino-1-naphthalene-sulfonic acid - C10H6NH2(SO3H) Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAall aqueous; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAall aqueous; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAall aqueous; Data valid for lining applications
2-aminoethanol - HOCH2CH2NH2 Group:
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDCCtech. pure; Data valid for lining applications
2-aminopentanedioic acid - HOOCCH(NH2)CH2CH2COOH Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAsaturated; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAsaturated; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAsaturated; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAAsaturated; Data valid for lining applications
2-butanone - CH3COCH2CH3 Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAtech. pure; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDCtech. pure; Data valid for lining applications
2-chloro-1-hydroxybenzene - C6H4OHCl Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AData valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAData valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAData valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAData valid for lining applications
2-ethylhexyl alcohol - CH3(CH2)3CH(CH2OH)C2H5 Group:
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
100AAAAAAData valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
100AAAAAAData valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
100AAAAData valid for lining applications
2-hydroxyethylamine - HOCH2CH2NH2 Group:
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDCCtech. pure; Data valid for lining applications
2-methyl-2-propanol - (CH3)3COH Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAtech. pure; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAtech. pure; Data valid for lining applications
2-naphthylamine-1-sulfonic acid - C10H6NH2(SO3H) Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAall aqueous; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAall aqueous; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAall aqueous; Data valid for lining applications
2-propanone - CH3COCH3 Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAtech. pure; Data valid for lining applications
10AAAC10% aqueous; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
10AAAAAA10% aqueous; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
10AAAAAA10% aqueous; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDCtech. pure; Data valid for lining applications
10AAC10% aqueous; Data valid for lining applications
2-propyn-1-ol - C3H3OH Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
7AA7% aqueous; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
7AAAAAA7% aqueous; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
7AAAAAA7% aqueous; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
7AB7% aqueous; Data valid for lining applications

Legend

A: Material is resistant

B: Change of properties can occur

C: Material is not resistant due to change of properties

The ratings given here are intended as a guide only and not as an alternative to actual testing. Therefore in practice, it is strongly recommended to carry out preliminary tests on a prototype under actual service conditions, to evaluate the final suitability of the selected plastics material for your application.

2007-2013 © the Quadrant group of companies. All rights reserved.