Symalit® Fluoroplastics Materialien

Please enter search term:

Lactic acid - CH3CHOHCOOH Group: Organic acids
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 60 °C 75 °C 100 °C 125 °C 150 °C Remarks
10AAA10% aqueous; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 60 °C 75 °C 100 °C 125 °C 150 °C Remarks
10AAAAAA10% aqueous; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 60 °C 75 °C 100 °C 125 °C 150 °C Remarks
10AAAAAA10% aqueous; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 60 °C 75 °C 100 °C 125 °C 150 °C Remarks
10AAA10% aqueous; Data valid for lining applications
Lanolin - Lanolin - Group: Other hydrocarbons (oils, fuels…)
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAtech. pure; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAAAtech. pure; Data valid for lining applications
Lauric acid - CH3(CH2)10COOH Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAData valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAData valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAData valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAAData valid for lining applications
Lauryl chloride - C12H25Cl Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAtech. pure; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAAtech. pure; Data valid for lining applications
Lauryl sulfate - (C12H25)2SO4 Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAtech. pure; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAAtech. pure; Data valid for lining applications
Laurylmercaptan - C12H25SH Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAtech. pure; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAAtech. pure; Data valid for lining applications
Lead acetate - Pb(C2H3O2)2 . 3H2O Group: Inorganic salt
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAsaturated; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAsaturated; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAsaturated; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAAsaturated; Data valid for lining applications
Lead fluoborate - Pb(BF4)2 Group:
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
50AAAAAAData valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
50AAAAAAData valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
50AAAAData valid for lining applications
Levulinic acid - CH3CO(CH2)2COOH Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAall aqueous; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAall aqueous; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAall aqueous; Data valid for lining applications
Lichenic acid - HOOCCH:CHCOOH Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAsaturated; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAsaturated; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAsaturated; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAsaturated; Data valid for lining applications
Lime - CaO Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAData valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAData valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAData valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAData valid for lining applications
Lime nitrate - Ca(NO3)2 Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
50AAAAAA50% aqueous; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
50AAAAAA50% aqueous; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
50AAAAAA50% aqueous; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
50AAAA50% aqueous; Data valid for lining applications
Linoleic acid - CH3(CH2)4CH:C3H4:CH(CH2)7COOH Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAtech. pure; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAAtech. pure; Data valid for lining applications
Linoleic oil - (CH3CH2CH:)3CH(CH2)7COOH Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAtech. pure; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAAAtech. pure; Data valid for lining applications
Linolic acid - CH3(CH2)4CH:C3H4:CH(CH2)7COOH Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAtech. pure; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAAtech. pure; Data valid for lining applications
Linseed oil - Linseed oil - Group: Other hydrocarbons (oils, fuels…)
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAtech. pure; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAAAtech. pure; Data valid for lining applications
Liqueurs - Liqueurs Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C Remarks
AAAAusual commercial; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C Remarks
AAAAusual commercial; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C Remarks
AAAAusual commercial; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C Remarks
UDAAAusual commercial; Data valid for lining applications
Liquid rosin - Tall oil - Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAtech. pure; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAAAtech. pure; Data valid for lining applications
Lithium bromide - LiBr Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAsaturated; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAsaturated; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAsaturated; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAAsaturated; Data valid for lining applications
Lithium chloride - LiCl Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAall aqueous; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAall aqueous; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAall aqueous; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAACall aqueous; Data valid for lining applications
Lithium hydroxide - LiOH Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAall aqueous; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAall aqueous; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAall aqueous; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDCall aqueous; Data valid for lining applications
Lubricating oil - Lubricating oil Group:
Symalit® ECTFE 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAtech. pure; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
AAAAAAtech. pure; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT 50 °C 75 °C 100 °C 125 °C 150 °C Remarks
UDAAAAAAtech. pure; Data valid for lining applications
Luminous gas - H2+CH4+CO(50:32:7%) Group:
Symalit® ECTFE 1000 linings
Concentration RT Remarks
Ausual comm.; Data valid for lining applications
Symalit® FEP 1000 linings
Concentration RT Remarks
Ausual comm.; Data valid for lining applications
Symalit® PFA 1000 linings
Concentration RT Remarks
Ausual comm.; Data valid for lining applications
Symalit® PVDF 1000 linings
Concentration RT Remarks
UDAusual comm.; Data valid for lining applications

Beständigkeiten

A: Das Material ist resistent

B: Veränderungen der Eigenschaften können eintreten

C: Das Material ist nicht resistent, da sich die Eigenschaften verändern

Zu beachten ist, dass die in dieser Datenbank aufgeführten Beständigkeitsbewertungen nur als Richtangaben und nicht als eine Alternative zu einer Praxiserprobung zu betrachten sind. Daher empfiehlt Quadrant Engineering Plastic Products ausdrücklich einen Test unter Praxisbedingungen durchzuführen, um die endgültige Eignung des gewählten Kunststoffs für den konkreten Einsatzzweck zu bewerten.