Please enter search term:
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | B | usual comm.; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | usual comm.; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | usual comm.; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | usual comm.; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | C | Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | B | Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | C | Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | B | C | all aqueous; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | B | C | all aqueous; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | C | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | C | Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | C | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | tech. pure; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | C | tech. pure; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | C | tech. pure; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| 50 | A | A | A | 50% aqueous; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| 50 | A | A | A | A | A | A | 50% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| 50 | A | A | A | A | A | A | 50% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | C | tech. pure; Data valid for lining applications | |||
| 50 | A | A | C | 50% aqueous; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | C | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | B | tech. pure; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | C | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | C | C | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | B | B | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| B | C | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | B | tech. pure; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | B | Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | B | Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | tech. pure; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | C | Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | ||||
|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | ||||
|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | ||||
|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | Remarks |
| UD | C | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | B | C | tech. pure; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | B | C | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | C | Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | B | Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 30 | A | B | B | 30% aqueous; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 30 | A | A | A | A | A | A | 30% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 30 | A | A | A | A | A | A | 30% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 30 | A | 30% aqueous; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | saturated; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | saturated; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | B | C | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | tech. pure; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | ||||||
|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | ||||||
|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | Remarks |
| A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | ||||||
|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | Remarks |
| A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | ||||||
|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | Remarks |
| UD | A | A | tech. pure; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | B | B | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | tech. pure, Auflösung; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | C | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | B | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | traces; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | traces; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | traces; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | tech. pure; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | ||||
|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | ||||
|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | ||||
|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | Remarks |
| UD | B | C | tech. pure; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | C | tech. pure; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | B | B | tech. pure; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | tech. pure; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | B | tech. pure; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| 10 | A | A | A | C | 10% aqueous; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | tech. pure; Data valid for lining applications | |||||
| 10 | A | A | C | 10% aqueous; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | gaseous; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | gaseous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | gaseous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | gaseous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | B | tech. pure; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | C | tech. pure; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | B | C | tech. pure; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | B | C | tech. pure; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | C | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | C | C | C | C | C | Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | B | C | tech. pure; Data valid for lining applications | |
Beständigkeiten
A: Das Material ist resistent
B: Veränderungen der Eigenschaften können eintreten
C: Das Material ist nicht resistent, da sich die Eigenschaften verändern
Zu beachten ist, dass die in dieser Datenbank aufgeführten Beständigkeitsbewertungen nur als Richtangaben und nicht als eine Alternative zu einer Praxiserprobung zu betrachten sind. Daher empfiehlt Quadrant Engineering Plastic Products ausdrücklich einen Test unter Praxisbedingungen durchzuführen, um die endgültige Eignung des gewählten Kunststoffs für den konkreten Einsatzzweck zu bewerten.