| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | B | B | B | B | Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | saturated; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | saturated; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | B | B | saturated; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | A | A | 50% aqueous; Data valid for lining applications |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | A | A | 50% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | A | A | 50% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 50 | A | A | A | A | 50% aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | all aqueous; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | all aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | all aqueous; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | all aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | saturated; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | saturated; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 10 | A | A | A | A | 10% aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | moist; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | moist; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | moist; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | A | moist; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | 100% gas; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | 100% gas; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | 100% gas; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | traces; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | traces; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | traces; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | A | traces; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||
|---|---|---|---|
| Concentration | RT | 50 °C | Remarks |
| A | liquid; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||
|---|---|---|---|
| Concentration | RT | 50 °C | Remarks |
| A | A | liquid; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||
|---|---|---|---|
| Concentration | RT | 50 °C | Remarks |
| A | A | liquid; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||
|---|---|---|---|
| Concentration | RT | 50 °C | Remarks |
| UD | B | B | gaseous; Data valid for lining applications |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | tech. pure; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | tech. pure; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||
|---|---|---|---|
| Concentration | RT | 50 °C | Remarks |
| A | liquid; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||
|---|---|---|---|
| Concentration | RT | 50 °C | Remarks |
| A | A | liquid; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||
|---|---|---|---|
| Concentration | RT | 50 °C | Remarks |
| A | A | liquid; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||
|---|---|---|---|
| Concentration | RT | 50 °C | Remarks |
| UD | B | B | gaseous; Data valid for lining applications |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | all aqueous; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | all aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | saturated; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | C | Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | B | Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | tech. pure; Data valid for lining applications | ||||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | B | tech. pure; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 10 | A | 10% aqueous; Data valid for lining applications | |||||
| 20 | A | 20% aqueous; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| 20 | A | A | A | A | A | A | 20% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 10 | A | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| 20 | A | A | A | A | A | A | 20% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 10 | A | 10% aqueous; Data valid for lining applications | |||||
| 20 | A | 20% aqueous; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | B | B | saturated; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | liquid blistering possible, without UV; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | liquid blistering possible, without UV; Data valid for lining applications; liquid blistering possible | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | liquid; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | C | gas 97% blistering possible, without UV; Data valid for lining applications | ||
| Symalit® PVDF Flex linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | C | C | gas 97% blistering possible, without UV; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| C | atomic = Cl blistering possible, without UV; Data valid for lining applications | ||||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | B | B | atomic = Cl blistering possible, without UV; Data valid for lining applications; atomic = Cl blistering possible, without UV | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | B | B | atomic = Cl blistering possible, without UV; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| C | atomic = Cl blistering possible, without UV; Data valid for lining applications | ||||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 25 | A | A | A | A | Data valid for lining applications | ||
| 100 | A | A | gas; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 25 | A | A | A | A | A | A | Data valid for lining applications |
| 100 | A | A | A | A | A | A | gas; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 25 | A | A | A | A | A | A | Data valid for lining applications |
| 100 | A | A | A | A | A | A | gas; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 25 | B | B | B | B | B | Data valid for lining applications | |
| 100 | B | B | B | B | B | 100% gas; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||
|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | Remarks |
| A | A | A | C | anhydrous blistering possible, without UV; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | saturated; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | saturated; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| 50 | A | A | A | A | B | 50% aqueous; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| 50 | A | A | A | A | A | A | 50% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| 50 | A | A | A | A | A | A | 50% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | B | tech. pure; Data valid for lining applications | |||
| 50 | A | A | A | A | 50% aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | C | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | B | C | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | Data valid for lining applications | |||||
| 100 | A | Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | Data valid for lining applications | ||||
| 100 | A | A | A | B | Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | tech. pure; Data valid for lining applications | ||||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | B | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | C | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | C | tech. pure; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | B | Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||
|---|---|---|---|
| Concentration | RT | 50 °C | Remarks |
| A | liquid; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||
|---|---|---|---|
| Concentration | RT | 50 °C | Remarks |
| A | A | liquid; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||
|---|---|---|---|
| Concentration | RT | 50 °C | Remarks |
| A | A | liquid; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||
|---|---|---|---|
| Concentration | RT | 50 °C | Remarks |
| UD | B | B | gaseous; Data valid for lining applications |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | tech. pure; Data valid for lining applications | ||||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | tech. pure; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | Data valid for lining applications | ||||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | B | B | Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | B | B | tech. pure; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||
|---|---|---|---|
| Concentration | RT | 50 °C | Remarks |
| A | B | Temp.<40°; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||
|---|---|---|---|
| Concentration | RT | 50 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||
|---|---|---|---|
| Concentration | RT | 50 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||
|---|---|---|---|
| Concentration | RT | 50 °C | Remarks |
| UD | B | C | tech. pure; Data valid for lining applications |
| Symalit® ECTFE 1000 linings | ||||||
|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | ||||||
|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | Remarks |
| A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | ||||||
|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | Remarks |
| A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | ||||||
|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | Remarks |
| UD | C | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | saturated; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | tech. pure; Data valid for lining applications | |||
| 50 | A | A | A | A | Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| 50 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| 50 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | tech. pure; Data valid for lining applications | |||
| 50 | A | A | A | Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | all; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | B | all; Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | saturated; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | all; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | B | all; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | Concentr:15:35:50; Data valid for lining applications | ||||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Concentr:15:35:50; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Concentr:15:35:50; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | B | Concentr:15%H2SO4:50%CrO3:35%H2O; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | tech. pure; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | tech. pure; Data valid for lining applications | |||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | tech. pure; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | saturated; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | ||||||
|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | Remarks |
| 10 | A | A | A | A | 10% aqueous; Data valid for lining applications | |
| Symalit® FEP 1000 linings | ||||||
|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | Remarks |
| 10 | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | ||||||
|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | Remarks |
| 10 | A | A | A | A | A | 10% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | ||||||
|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | Remarks |
| 10 | A | A | A | A | 10% aqueous; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||
|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | Remarks |
| A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||
|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | Remarks |
| A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||
|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | Remarks |
| A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | tech. pure; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | C | C | tech. pure; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | all aqueous; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | all aqueous; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | tech. pure; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | saturated; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | saturated; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | saturated; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 90 | A | A | A | 90% aqueous; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 90 | A | A | A | A | A | A | 90% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 90 | A | A | A | A | A | A | 90% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 90 | A | B | C | 90% aqueous; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 90 | A | A | A | 90% aqueous; Data valid for lining applications | |||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 90 | A | A | A | A | A | A | 90% aqueous; Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 90 | A | A | A | A | A | A | 90% aqueous; Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 90 | A | B | C | 90% aqueous; Data valid for lining applications | |||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | tech. pure; Data valid for lining applications | ||||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | B | tech. pure; Data valid for lining applications | ||||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | Data valid for lining applications | ||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | A | Data valid for lining applications |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| 100 | A | A | A | A | A | Data valid for lining applications | |
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | tech. pure; Data valid for lining applications | ||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | A | A | A | tech. pure; Data valid for lining applications | ||
| Symalit® ECTFE 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | tech. pure; Data valid for lining applications | |||||
| Symalit® FEP 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PFA 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| A | A | A | A | A | A | tech. pure; Data valid for lining applications | |
| Symalit® PVDF 1000 linings | |||||||
|---|---|---|---|---|---|---|---|
| Concentration | RT | 50 °C | 75 °C | 100 °C | 125 °C | 150 °C | Remarks |
| UD | A | C | tech. pure; Data valid for lining applications | ||||
Beständigkeiten
A: Das Material ist resistent
B: Veränderungen der Eigenschaften können eintreten
C: Das Material ist nicht resistent, da sich die Eigenschaften verändern
Zu beachten ist, dass die in dieser Datenbank aufgeführten Beständigkeitsbewertungen nur als Richtangaben und nicht als eine Alternative zu einer Praxiserprobung zu betrachten sind. Daher empfiehlt Quadrant Engineering Plastic Products ausdrücklich einen Test unter Praxisbedingungen durchzuführen, um die endgültige Eignung des gewählten Kunststoffs für den konkreten Einsatzzweck zu bewerten.